Problem summary
The engine reaches firing speed, then the governor commands fuel reduction before the start sequence completes. Available start-air pressure is within the expected range.
Secure vessel workspace
DG No.2 start failure
Logged
Today · 14:08
Mode
Standby start
Engineer
2/E D. Okafor
Engineer observation
DG reaches 700 RPM during starting, governor pulls the fuel rack back and Start Failure occurs.
Evidence attached
4 items
START FAIL 14:08
Governor linkage
PDF manual
Yanmar 6EY18AL Operation Manual
Measurement
Start air 27.8 bar
Technical assessment
Evidence-based preliminary guidance
Problem summary
The engine reaches firing speed, then the governor commands fuel reduction before the start sequence completes. Available start-air pressure is within the expected range.
Most likely causes
Governor actuator feedback mismatch
Position feedback may not follow commanded fuel during transition through 600–750 RPM.
Fuel-rack linkage resistance
Binding or delayed return can trigger protective start-failure logic.
Start sequence permissive input
Review start-failure relay and governor-ready input status.
Diagnostic steps
0 of 3 loggedConfirm start-air pressure remains above 25 bar.
Observe governor actuator command during 600–750 RPM.
Inspect fuel-rack linkage for sticking before a repeated start attempt.
Measurements to check
Safety notes
Keep personnel clear of linkage travel. Verify turning gear, local emergency stop, and fuel shut-off status under vessel procedure before inspection.
Recommended action
Perform a stationary linkage movement check, then capture actuator command and feedback during one controlled start attempt. Escalate to the electrical governor circuit if mismatch exceeds the manual tolerance.
Do not defeat overspeed, start-failure, or interlock protections.